Kunshan Security Company Jiusheng Computer Room Equipment Management Guidelines
[2023-11-15]

Smart-UPS RT
Management guidelines
Kunshan Security Company Jiusheng
Talking about Engineering in the Property Industry
Ordinary people have such a misconception
Think it's just repairing the elevator
Lighting, air conditioning, network, etc
In fact that was not the case.
Our engineers have another important task
These places are rarely noticed or even overlooked
But it is the core of the entire facility management
Just like the CPU of a computer, the heart of a person
It is hidden in inconspicuous corners such as buildings and basement
it
It's the equipment room in the property industry
Reasonable layout, identification and differentiation of equipment room
The system is on the wall, the functional operation is visualized, and so on,
It reflects the security of Jiusheng
An important aspect of facility and equipment management level!
The following are our company's equipment management guidelines, please refer to:

Standardized management of computer rooms

Water pump room
Water pump room management standards:
1. Warning lines must be set up around water pumps, water pump controllers, and fire extinguishers;
2. The warning line shall be uniformly yellow or black alternating;
3. The width of the warning line is 10cm, the safety close range is 70cm, and the front of the fire extinguisher extends 30cm;
4. The warning line is clear and undamaged.

Management standards:
1. Install the wall files in a prominent position on the main entrance wall and use aluminum frames for installation;
2. The documents on the wall are all controlled documents, such as the "Operating Regulations";
3. The documents on the wall include the secondary water supply management system, emergency plan, and operating procedures.

Safety signs for water pump room:
1. The water pump room is prominently marked;
2. Clear and intact identification;
3. Standardized warning signs;
4. Warning sign specifications, materials, dimensions 270+240mm, 1.9 transparent acrylic+4.8mm PVC;
5. Identification plate 295+135mm, 4.8mm acrylic;
6. The distance from the bottom edge of the warning sign to the top of the door frame is 70cm, and the distance from the left and right door frames is 10cm.

Water supply system for water pump room:
1. Water supply pipeline for water pump room
2. Clear division of pipeline colors
3. Obvious warning line
4. Device identification (device name+status)

1. The water level line of the water tank is indicated by the warning value in red and the normal value in green;
2. Water pump room pressure gauge;
3. The warning line is obvious.

generator system

Management standards:
1. Warning lines and insulation pads must be set up around transformers, distribution cabinets, and fire extinguishers;
2. Unified use of yellow or black alternating colors;
3. The width of the warning line is 10cm, and the safe close range is 70cm;
4. The equipment label is clear and undamaged.


1.灭火器摆放在设备出入口1.5米内;
2.规格:2-4kg/瓶,数量为2瓶;
3.装箱摆放或灭火器离地20cm吊装;
4.每月检查一次,能正常使用。

Generator room management system:
1. Supervision column for certified employment;
2. Professional equipment work license;
3. Ensure that the license plate is clear and intact.

Power supply and distribution system

Power supply and distribution management standards:
1. Warning lines and insulation pads must be set up around transformers, distribution cabinets, and fire extinguishers;
2. Unified use of yellow or black alternating colors;
3. The width of the warning line is 10cm, and the safe close range is 70cm;
4. The equipment label is clear and undamaged.

Distribution room fire corner:
1. Special fire extinguisher
2. Gas fire extinguisher
3. Obvious safety warnings
4. Warning line alternating black and yellow
5. The ground is clean and tidy without any foreign objects

elevator machine room

Elevator machine room identification:
1. The location of the elevator machine room logo is prominent;
2. Clear and intact identification;
3. Standardized warning signs;
4. Warning sign specifications, materials, dimensions 270+240mm, 1.9 transparent acrylic+4.8mm PVC;

Fire control room

Monitoring room personnel information:
1. Day and night duty personnel
2. Wearing bareheaded photos and copies of identification documents on the wall

Monitoring room operation records:
1. Shift handover record in the monitoring room
2. Fire alarm records
3. Records of building fire protection treatment
4. Security monitoring system duty records
5. Entry and exit registration